APC Smart-UPS Ultra Series
3000VA 230V 1U, with Lithium-Ion Battery, with SmartConnect

APC Smart-UPS Ultra Series

*Please note: Product descriptions, specifications and part numbers have been sourced from www.apc.com and may refer to the US products which differ from products which will be supplied in Australia. Data sheets can be provided upon request for the Australian equivalent to these products.

Brings Smart-UPS reliability to entry-level applications.

This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 5KVA on-line 2U rackmount UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. It comes with Hardwired input and 6xC13+4xC19 IEC outlets. It embeded Management Card that enables graceful shutdown of physical servers, virtual machines & HCI Clusters via PowerChute Network Shutdown. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The UPS has a 5-year warranty on the UPS and Lithium-ion battery.


Smart-UPS Ultra Series - 230V Output / 230V Input
SRTL3KRM1UIC - APC Smart-UPS Ultra, 3000VA 230V 1U, with Lithium-Ion Battery, with SmartConnect

SRTL3KRM1UIC - APC Smart-UPS Ultra, 3000VA 230V 1U, with Lithium-Ion Battery, with SmartConnect

SRTL3KRM1UINC - APC Smart-UPS Ultra, 3000VA 230V 1U, with Lithium-Ion Battery, with Network Management Card Embedded

SRTL3KRM1UINC - APC Smart-UPS Ultra, 3000VA 230V 1U, with Lithium-Ion Battery, with Network Management Card Embedded

SRTL5KRM2UI - APC Smart-UPS Ultra On-Line Lithium ion, 5KVA/5KW, 2U Rack/Tower, 230V

SRTL3KRM1UINC - APC Smart-UPS Ultra On-Line Lithium ion, 5KVA/5KW, 2U Rack/Tower, 230V

Features & Benefits:

Features
Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
LCD Status Display Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
High online efficiency Reduces utlility costs, generates less heat.
Cold-start capable Provides temporary battery power when the utility power is out.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Availability
Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Manageability
Network manageable Provides remote management of the UPS over the network.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators Quickly understand unit and power status with visual indicators.
Serial Connectivity Provides management of the UPS via a serial port.
USB connectivity Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification Warns when a battery is not available to provide backup power.
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers Enables a quick recovery from overload events.
Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Adaptability
Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Safety
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.